Email Us

UltraScan Head

UltraScan products cover a comprehensive range of models: 10/14/20/30/50mm aperture 2D Galvanometers, 14/20/30mm aperture 3D galvanometers. This 2 axis mirror galvanometer coating selection is rich, UV, green, fiber, CO2 and other coating options, strict mirror quality, to ensure the requirements of mirror flatness and damage threshold. The driver board adopts class D power amplifier, with high output power, small heating and small drift. Strict factory inspection standards ensure the quality of the galvo head laser and very low repair rate.

GET A QUOTE
2 axis galvanometer
2 axis galvanometer
2 axis mirror galvanometer
fiber laser galvo head
galvo head co2 laser
scan heads

Key Features Of UltraScan Head


  • Low noises, high linearity and low drift


  • Modular design, easy installment and maintenance


  • Support varieties of F-theta lenses


  • Available to general protocol (XY2-100) and other protocol


Download
  • Ultrascan 10mm Analog Dimensions
  • Ultrascan 10mm Digital Dimensions
  • Ultrascan 14mm Dimensions
  • Ultrascan 20mm Dimensions
  • Ultrascan 30mm Dimensions
  • Ultrascan 50mm Analog Dimensions
Show More
Leave a Message
*
*
*
*
*

Specifications Of UltraScan Head



UltraScan I

UltraScan14

UltraScan20

UltraScan30

UltraScan50

Input Beam Aperture (mm)

14

20

30

50

Beam Displacement (mm)

16.42

25.25

35.61

62.25

Tracking Error (ms)

0.23

0.45

0.70

1

Repeatability (µrad)

<2

<2

<2

<2

Offset Drift (µrad/K)

<15

<15

<15

<15

Gain Drift (ppm/K)

<80

<80

<80

<80

Long-term drift over 8 hours (mrad)

<0.3

<0.3

<0.3

<0.3

1% Of Full Scale (ms)

0.65

0.80

1.20

1.5

10% Of Full Scale (ms)

1.60

2.50

4.50

6.5

Positioning Speed (m/s)

10.0

5.0

3.0

1

Typical Scan Angle (°)

±25

±25

±25

±25

Gain Error (mrad)

<5

<5

<5

<5

Zero Offset (mrad)

<5

<5

<5

<5

Nonlinearity (%)

<0.4

<0.4

<0.4

<0.4

Power Requirements

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

Communication protocol

16bit:XY2-100  

20bit:ST2-100

16bit:XY2-100 

 20bit:ST2-100

16bit:XY2-100  

20bit:ST2-100

16bit:XY2-100 

 20bit:ST2-100

Operation Temperature (℃)

25±10

25±10

25±10

25±10

Weight (kg)

2.3

5.0

5.2

8.8



UltraScan II

UltraScan II 7

UltraScan II 10

UltraScan II 14

UltraScan II 20

UltraScan II 30

Input Beam Aperture (mm)

7

10

14

20

30

Beam Displacement (mm)

9.77

12.54

16.42

25.25

35.53

Tracking Error (ms)

0.15

0.12

0.15

0.35

0.6

Repeatability (µrad)

<2

<2

<2

<2

<2

Offset Drift (µrad/K)

<20

<12

<12

<12

<12

Gain Drift (ppm/K)

<100

<50

<50

<50

<50

Long-term drift over 8 hours (mrad)

<0.4

<0.15

<0.15

<0.15

<0.15

1% Of Full Scale (ms)

0.22

0.30

0.35

0.70

1.10

10% Of Full Scale (ms)

0.80

0.80

0.90

2.40

4.40

Positioning Speed (m/s)

25

18

14

6.0

4.0

Typical Scan Angle (°)

±25

±25

±25

±25

±25

Gain Error (mrad)

<5

<5

<5

<5

<5

Zero Offset (mrad)

<5

<5

<5

<5

<5

Nonlinearity (%)

<0.4

<0.4

<0.4

<0.4

<0.4

Power Requirements

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

Communication protocol

XY2-100  


XY2-100  


XY2-100  


XY2-100 


XY2-100  


Operation Temperature (℃)

25±10

25±10

25±10

25±10

25±10

Weight (kg)

1.6

2.3

2.3

5.0

5.2


Galvanometer Application

Please Contact Us!
TO KNOW MORE ABOUT HAN'S SCANNER PRODUCTS
Related 2-axis Galvo Scan Head
Global Leader Of Optical Scanning System Solutions
To Find More

4F Building4, Han's Laser Industry Park, 128 Chongqing Street, Fuyong, Bao'an District, Shenzhen City, Guang Dong, P.R. China.

US office address:4224 clay business Dr.,Katy,TX 77449,US
scanner@hanslaser.com +86 0755-27333701