The Extrascan is Chinese first fully digital scanning galvanometer for high precision and drift requirements. This 2 axis galvanometer model coverage: 10/14/20/30mm aperture 2D galvanometer;  3D galvanometer with 14/20/30mm aperture. Independent research and development of high precision grating encoder, break foreign technology monopoly, 23bit resolution digital galvanometer to achieve excellent positioning accuracy and repeated positioning accuracy.  Flexible configuration of FPGA-based digital drive board can match galvanometers with different loads from 10-30mm.

GET A QUOTE
galvo scan head
galvo scan head
galvo head laser
scan heads
laser scanner head

Key Features Of Extrascan Head


  • 2D galvanometer with 10/14/20/30mm aperture  


  • Independent research and development of high-precision grating encoder to achieve excellent positioning accuracy and repeated positioning accuracy  


  • Supports galvanometer position monitoring and position feedback to detect the status of the galvanometer in real time, ensuring safe and reliable operation of the galvanometer 

Download
  • Extrascan 10mm Dimensions
  • Extrascan 14mm Dimensions
  • Extrascan 20mm Dimensions
  • Extrascan 30mm Dimensions
Leave a Message
*
*
*
*
*

Specifications Of Extrascan Head


ExtraScan I

ExtraScan I 10

ExtraScan I 14

ExtraScan I 20

ExtraScan I 30

Input Beam Aperture (mm)

10

14

20

30

Beam Displacement (mm)

12.54

16.42

25.25

35.53

Tracking Error (ms)

0.3

0.40

0.65

1.2

Repeatability (µrad)

<1

<1

<1

<1

Offset Drift (µrad/K)

<15

<15

<15

<15

Gain Drift (ppm/K)

<8

<8

<8

<8

Long-term drift over 8 hours (mrad)

<0.1

<0.1

<0.1

<0.1

1% Of Full Scale (ms)

0.55

0.85

1.0

1.50

10% Of Full Scale (ms)

1.40

1.80

3.0

5.0

Positioning Speed (m/s)

7.0

5.0

3.0

2.0

Typical Scan Angle (°)

±25

±25

±25

±25

Gain Error (mrad)

<5

<5

<5

<5

Zero Offset (mrad)

<5

<5

<5

<5

Nonlinearity (%)

<0.1

<0.1

<0.1

<0.1

Power Requirements

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

Communication Protocol

16bit:XY2-100

20bit:ST2-100


16bit:XY2-100

20bit:ST2-100


16bit:XY2-100

20bit:ST2-100


16bit:XY2-100

20bit:ST2-100


Operation Temperature (℃)

25±10

25±10

25±10

25±10

Weight (kg)

1.9

2.3

5.0

5.2



ExtraScan II 

ExtraScan II 10

ExtraScan II 14

ExtraScan II 20

ExtraScan II 30

Input Beam Aperture (mm)

10

14

20

30

Beam Displacement (mm)

12.54

16.42

25.25

35.53

Tracking Error (ms)

0.2

0.25

0.5

0.80

Repeatability (µrad)

<1

<1

<1

<1

Offset Drift (µrad/K)

<15

<15

<15

<15

Gain Drift (ppm/K)

<8

<8

<8

<8

Long-term drift over 8 hours (mrad)

<0.08

<0.08

<0.08

<0.08

1% Of Full Scale (ms)

0.45

0.6

0.85

1.30

10% Of Full Scale (ms)

1.30

1.50

2.60

4.80

Positioning Speed (m/s)

10.0

7.0

5.0

3.0

Typical Scan Angle (°)

±25

±25

±25

±25

Gain Error (mrad)

<5

<5

<5

<5

Zero Offset (mrad)

<5

<5

<5

<5

Nonlinearity (%)

<0.1

<0.1

<0.1

<0.1

Power Requirements

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

±15VDC, ≥3A

Communication Protocol

16bit:XY2-100

20bit:ST2-100


16bit:XY2-100

20bit:ST2-100


16bit:XY2-100

20bit:ST2-100


16bit:XY2-100

20bit:ST2-100


Operation Temperature (℃)

25±10

25±10

25±10

25±10

Weight (kg)

1.9

2.3

5.0

5.2


Galvanometer Application

Please Contact Us!
TO KNOW MORE ABOUT HAN'S SCANNER PRODUCTS
Related 2-axis Galvo Scan Head
Global Leader Of Optical Scanning System Solutions
To Find More

4F Building4, Han's Laser Industry Park, 128 Chongqing Street, Fuyong, Bao'an District, Shenzhen City, Guang Dong, P.R. China.

US office address:4224 clay business Dr.,Katy,TX 77449,US
scanner@hanslaser.com +86 0755-27333701